Design a two-finger gripper in SolidWorks, adapted from the GL-Robot linkage in an RSS 2024 research paper, in which a lead screw drives each 3-joint finger to wrap around objects.
Reverse-engineered the finger linkage from the paper's figures by scaling from a known 60 mm dimension, and checked the result against two other labeled dimensions to within 1 mm.
Build the link parts from one shared skeleton sketch, and size the M4 pivot joints with edge-distance and fit rules so the links turn freely on McMaster-Carr hardware.